15
FANUC Series 16i /18i -MA
Spindle electronic gear box
S
ecifications
EDT. DATE DESIG. DESCRIPTION PAGE /19
A – 77833E
NO.
TITLE
NEWLY
1999.July.28
01
3.2 Parameters for synchronous control
[Data type] Bit axis
HBR The synchronization is :
0 : Canceled by reset.
1 : Not canceled by reset.
1 is usually specified.
HDR Setting of the direction for helical gear compensation
(1 is usually specified.)
[Data type] Byte
[Valid data range] 1 to the maximum number of controlled axes
This parameter sets the number of the axial feed axis for a helical gear. If the
value out of the valid range is specified, 3(the 3
rd
axis) is specified.
[Data type] Byte
[Valid data range] 1 to the maximum number of controlled axes
This parameter sets the number of the slave axis for Spindle EGB control.
If the value out of the valid range is specified, 4(the 4
th
axis) is specified. The
slave axis number should be set larger than the master axis number (No.7771).
[Data type] Byte
[Valid data range] 1 to the maximum number of controlled axes
This parameter sets the number of the master axis for Spindle EGB control.
The master axis number should be set smaller than the master axis number
(No.7710).
7709
Axis number of the axial feed axis for helical gear compensation
7700
HDR
HBR
76543210
Note
After setting this parameter, the power must be turned off then on again.
7710
Axis number of the slave axis for Spindle EGB control
Note
After setting this parameter, the power must be turned off then on again.
7771
Axis number of the master axis for Spindle EGB control
Note
After setting this parameter, the power must be turned off then on again.