Preventive measures against errors
of linear scale caused by noise
A-65434EN
to GROUND
SIGNAL GROUND
M3 screw terminal
SDU :
A02B-0236-C203
or
A02B-0236-C205
GROUNDING WIRE

Contents Summary of FS 16i/18i/21i/20i/160i/180i/210i/15i/150i/Power Mate i ,etc. Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) No. TMN01/178E Date 2001 General Manager of Hardware Laboratory Preventive measures against errors of linear scale caused by noise Communicate this report to : O Your information O GE Fanuc-N, GE Fanuc-E FANUC Robotics CINCINNATI MILACRON O Machine tool builder Sales agency
  • Page 2Preventive measures against errors of linear scale caused by noise 1. Outline In this material, several preventive measures against errors of linear scale caused by noise in the system of FANUC Series 16i/ 18i/ 21i/ 20i/ 160i/ 180i/ 210i/ 15i/ 150i/ Power Mate i ,etc. are shown. 2. Preventive measur
  • Page 3SDU : SIGNAL GROUND A02B-0236-C203 M3 screw terminal or GROUNDING WIRE A02B-0236-C205 to GROUND Preventive measures against errors TITLE of linear scale caused by noise DRAW. No. A-65434EN EDIT DATE DESIGN DESCRIPTION FANUC LTD Page 2/4
  • Page 43. Axis Vibration The error of linear scale may not cause alarm but cause axis vibration. If the servo software is following edition, the feedback interpolation counter can be used to investigate the influence of the noise. l 90A0/X,Y l 90A6/A or later l 90B0/D or later Note) feedback interpolation
  • Page 54x1202DA : Axis which No.1023 is set to 12. 4x1402CA : Axis which No.1023 is set to 13. 4x1402DA : Axis which No.1023 is set to 14. 4x1602CA : Axis which No.1023 is set to 15. 4x1602DA : Axis which No.1023 is set to 16. 4x1802CA : Axis which No.1023 is set to 17. 4x1802DA : Axis which No.1023 is set