(5) Move the master or the slave axis in the direction where the synchronous error
decreases, with checking the synchronous error (Diagnose No.3500).
The movement in the direction where the synchronous error increases is
neglected (But, when the parameter No.1803#3=1, the movement even in the
direction where the synchronous error increases is available. So, be careful.)
Check the movement of the machine carefully.
(6) When the synchronous error has become small enough not to generate the alarm
of SV024, the mode is changed from the correction mode to the normal mode.
The compensation and the check of the synchronous error re-starts.
(7) “The alarm in the correction mode” is canceled with Reset.
(note) When the over flow alarm(SV011) of the position control circuit is also
displayed, the value of the synchronous error is not displayed correctly. Then,
turn off/on the power, and correct the synchronous error with the
synchronization initiation.