2.Display (Diagnose)
As the data for the synchronization, the following two data are displayed on the
diagnostic screen.
Unit:Detection unit
The synchronous error is displayed with the detection unit.
Unit:Detection unit
The total value of the compensation is displayed.
(※)
These data are displayed on the master axes.
No data are displayed on the slave axes.
7/011
Data No.
3501
Data
Synchronous error of 1st axis
Synchronous error of 2nd axis
:
Synchronous error of 10th axis
Data No.
3500
Data
The total value of the synchronous error
compensation of 1st axis
The total value of the synchronous error
compensation of 2nd axis
:
The total value of the synchronous error
compensation of 10th axis