02
01.09.17
11/25
Descri
tion DesigDate Ed
01
99.06.01
SHEET
DRAW. No.
CUST.
TITLE
Genma
Okita Newl
desi
ned
Standard settin
is chan
ed.
The parameter list for High speed
and High precision cutting
-62449E-064
03
04.09.17
Standard setting is changed.
Out of frame (3) is added / changed.
The parameters in which the fixed values are set and which you need not change generally
Parameter
No.
Standard
setting value
Meaning
#6,#3
1 . 0
Linear acc/dec after interpolation (In case Bell shaped acc/dec before
interpolation)
1602#6,#3
1 , 1
Bell shaped acc/dec after interpolation (In case linear acc/dec before
interpolation)
1603#7 1
Bell acc/dec before interpolation (0:Linear acc/dec before interpolation)
1802#7 0/1
In case that the CMR setting is equal to or greater than 2 (the setting value of
parameter No.1820 is equal to or greater than 4), please set “1”.
7050#5 1
Please set the standard setting value.
7050#6 0
Please set the standard setting value.
7052#0 0/1
PMC axis or Cs axis is set to 1.
7055#3 1/0
Set to 1 when Look-Ahead Bell-Shaped Acceleration/Deceleration Before
Interpolation Time Constant Change Function is used
7058 0
Please set the standard setting value.
7066
mm / inch
10000 / 3937
Reference feedrate for Look-Ahead Bell-Shaped Acceleration/Deceleration
Before Interpolation Time Constant Change Function
(3)