02
01.09.17
4/25
Descri
tion DesigDate Ed
01
99.06.01
SHEET
DRAW. No.
CUST.
TITLE
Genma
Okita Newl
desi
ned
Standard settin
is chan
ed.
The parameter list for High speed
and High precision cutting
-62449E-064
03
04.09.17
Standard setting is changed.
Out of frame (3) is added / changed.
The parameters which require adjustments according to the kind of the machine
Standard setting value
Parameter
No.
Standard Velocity
priority
I
Velocity
priority
II
Meaning
1478 400.0 500.0 1000.0
Allowable feedrate difference for the deceleration based
on feedrate difference at a corner (mm/min)
1635 24 16 16
Time constant for acceleration/deceleration after
interpolation during look-ahead acc/dec mode (msec)
1656 64 48 32
Time constant for look ahead bell-shaped acceleration/
deceleration (Time for acceleration rate change) (msec)
1660 700.0 2000.0 4000.0
Acceleration rate for look-ahead acc/dec before
interpolation
(Acceleration of each axis is set in the unit of mm/sec
2
)
1663 525.0 1500.0 3000.0
Allowable acceleration of each axis for deceleration based
on acceleration of each axis (HPCC mode)
(Acceleration of each axis is set in the unit of mm/sec
2
)
1665 525.0 1500.0 3000.0
Allowable acceleration of each axis for deceleration based
on acceleration during circular interpolation (Normal mode)
(Acceleration of each axis is set in the unit of mm/sec
2
)
The parameters that the fixed values are set and need not change generally.
Parameter
No.
Standard
setting value
Meaning
1483 100.0
Lower limit feedrate for deceleration based on acceleration (HPCC mode)
(mm/min)
1491 100.0
Lower limit feedrate for deceleration based on acceleration (Normal mode)
(mm/min)
1517#6 0
Deceleration method for deceleration based on feedrate difference and
acceleration
0: Compatible with 15B
(Allowable feedrate difference and acceleration are used up to the limit)
1: Feedrate is constant if the curvature is the same even if the direction
changes.
1600#4 0
0: Linear or bell-shaped acceleration/deceleration after interpolation (*1)
1: Exponential acceleration/deceleration after interpolation
1603#3 1/0
Set to 1 when Look-Ahead Bell-Shaped Acceleration/Deceleration Before
Interpolation Time Constant Change Function is used (*2)
1473
mm / inch
10000.0/3937.0
Reference feedrate for Look-Ahead Bell-Shaped Acceleration/Deceleration
Before Interpolation Time Constant Change Function (*2)
2401#6 0
When this parameter is set to 1, look-ahead acc/dec and multi-buffer
becomes effective at power on and in the clear state.
When the option of Fine HPCC is selected, Fine HPCC becomes effective at
the same time.
When this parameter is set to 0, look-ahead acc/dec mode and fine HPCC
mode becomes effective by G05.1Q1 command
(3)
(3)
(3)
(3)
(3)
(3)
(3)