EDT
rvPersn
DATE
DESIG.
DESCRIPTION
Date
FANUC Series 30i/31i/32i-A, 31i-A5
TWIN-TABLE CONTROL
A-90176EN
15/21
Name No.
Page
FANUC LTD.
8337 M code for turning off synchronization in feed axis synchronous control
or twin table control
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 1 to 999999999
This parameter specifies an M code for switching from synchronous operation to
normal operation.
The M code set in this parameter is not buffered.
8338 M code for turning on synchronization in feed axis synchronous control
or twin table control
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 1 to 999999999
This parameter specifies an M code for switching from normal operation to
synchronous operation.
The M code set in this parameter is not buffered.
8339 M code for independent operation in twin table control
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 1 to 999999999
Specify the M code that causes switching from synchronous or normal operation to
independent operation.
The M code specified for this parameter is handled as an M code without buffering.