Change of the DeviceNet board specification in FS16i/18i/21i/160i/180i/210i/160is/180is/210is-MODEL A/B and Power Mate i-MODEL D/H Additional Manual Page 3

Additional Manual
3. Order specification for board
Only board and software are changed. Other item and remarks on the Order List are not changed.
a) FS16i/18i/21i/160i/180i/210i/160is/180is/210is-MODEL A/B
Table 1
Item
Old order
Specification
New order specification
DeviceNet board Refer to Table 2.
Control software A02B-0236-J564#6570 A02B-0236-J564#6571
Application software A02B-0236-J565#6576
(No changed)
Since 04th edition.
Master function A02B-0xxx-S723 (No changed)
Slave function A02B-0xxx-S724 (No changed)
HIROSE HR31 contact A02B-0259-K211 (No changed)
Note 1) Refer to Order List about "xxx".
Note 2) Specify HIROSE HR31 contact for board B.
Table 2
System
(board name)
The present
order specification
New order
specification
New board
number
LCD-mounted type
Model-A
A02B-0236-J301 A02B-0236-J302 A20B-8001-0881
Stand-alone type
Model-A
( slave board )
A02B-0265-J300 A02B-0265-J305 A20B-8100-0492
Stand-alone type
Model-A
( master board )
A02B-0265-J301 A02B-0265-J306 A20B-8100-0492
Stand-alone type
Model-A
( slave board B )
A02B-0265-J302 A02B-0265-J307 A20B-8100-0493
Stand-alone type
Model-A
( master board B )
A02B-0265-J303 A02B-0265-J308 A20B-8100-0493
LCD-mounted type
Model-B
A02B-0281-J301 A02B-0281-J305 A20B-8001-0881
Stand-alone type
Model-B
( slave board B )
A02B-0281-J302 A02B-0281-J306 A20B-8100-0493
Stand-alone type
Model-B
( master board B )
A02B-0281-J303 A02B-0281-J307 A20B-8100-0493
Edit. DATE Design
Description
DRAW. NO.
A-77221EN
CUST.
01 03/06/05
New issued
AJIMA
TITLE
Change of the DeviceNet board in FS16i/18i/21i/
160i/180i/210i/160is/180is/210is-MODEL A/B and
Power Mate i-D/H
SHEET
2 / 4

Contents Summary of Change of the DeviceNet board specification in FS16i/18i/21i/160i/180i/210i/160is/180is/210is-MODEL A/B and Power Mate i-MODEL D/H Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) NO. TMN03/051E Date 10 Jun, 2003 General Manager of CNC Laboratory Change of the DeviceNet board specification in FS16i/18i/21i/160i/180i/210i/160is/180is/210is-MODEL A/B and Power Mate i-MODEL D/H 1. Communicate this report to : ○ Your information ○ GE Fanuc-N, GE Fanuc-E
  • Page 2Change of DeviceNet board Abstract In FS16i/18i/21i/160i/180i/210i/160is/180is/210is-MODEL A/B and Power Mate i-MODEL D/H, FANUC will apply the new DeviceNet board because parts on the board is stopped manufacturing. It is necessary to change the order specification and board number. Please pay atte
  • Page 33. Order specification for board Only board and software are changed. Other item and remarks on the Order List are not changed. a) FS16i/18i/21i/160i/180i/210i/160is/180is/210is-MODEL A/B Table 1 Old order Item New order specification Specification DeviceNet board Refer to Table 2. Control software
  • Page 4b) Power Mate i-MODEL D/H Table 3 Item Old order specification New order specification DeviceNet board Refer to Table 4. Control software A02B-0259-J554#6570 A02B-0259-J554#6571 (No changed) Application software A02B-0259-J553#6576 Since 04th edition. Master function A02B-0259-J860 (No changed) Slav
  • Page 54. Setting of parameter When the problem of excessive message traffic of the network occurs because new DeviceNet board was used, this problem can be avoided by adjusting the scanning interval of network. There is the item of “7 SCAN INTERVAL = “ on the DEVICENET MASTER SETTING screen to adjust the