EDIT DATE DESIG.
Small Machine operator’s panel
connection manual
TITLE
A-83122E
8 Specifications
8.1 Environmental Requirement
Temperature
Around a unit
At operation 0°C~55°C
Storing or transporting -20°C~60°C
Temperature
variance
Max. 1.1°C/min
Humidity Normally 75% or less (Relative humidity)
Short time(Within one month) 95% or less (Relative humidity)
Vibration Operating 0.5G or less
Atmosphere Normal FA atmosphere(Consult us when using the system under environments
with higher degree of dust, coolant, or organic solution.)
8.2 Order specification
Name Specification Note
Small Machine Operator’s Panel
A02B-0299-C150#M
M Series
Small Machine Operator’s panel
A02B-0299-C150#T
T Series
Fuse(Spare part)
A03B-0815-K001 1A
8.3 Operator’s panel specification
Item Specification Note
Key switches of Small
Machine operator’s panel
30 keys Matrix DI
LED Color : Green Attached to 21 key switches, Matrix DO
MPG interface Max. 3 units
Only available for i series.
CNC Interface FANUC I/O Link
connection
Max. 16 groups.
And total points max. 1024/1024 will be
available.
8.4 Power supply specification
Voltage Capacity Note
DC24V±10% (from Power
connector CA64, including
momentary values)
0.4A