OPERATION
8. DATA INPUT/OUTPUT
B–62094E/04
296
Offset data is loaded into the memory of the controller from a floppy or
NC tape. The input format is the same as for offset value output. See
section 8.5.2.
When an offset value is loaded which has the same offset number as an
offset number already registered in the memory, the loaded offset data
replaces existing data.
Inputting offset data
1 Make sure the input device is ready for reading
2 Press the EDIT switch on the machine operator’s panel.
3 When using a floppy, search for the required file according to the
procedure in Section 8.2.
4 Press function key
OFFSET
SETTING
.
5 Press soft keys
[(OPRT)].
6 Press rightmost soft key
(next menu key).
7 Press soft keys
[READ] and [EXEC].
8 The input offset data will be displayed on the screen after completion
of input operation.
1 Select the EDIT mode.
2 Display the data display screen by pressing
<VAR> key.
3 Perform the same operation as for program input.
4 The input offset data will be displayed on the screen after completion
of input operation.
8.5
OFFSET DATA INPUT
AND OUTPUT
8.5.1
Inputting Offset Data