OPERATION
11. SETTING AND DISPLAYING DATA
B–62094E/04
390
Displays common variables (#100 to #199, and #500 to #699) on the CRT.
When the absolute value for a common variable exceeds 99999999,
******** is displayed. The values for variables can be set on this screen.
Relative coordinates can also be set to valiables.
Procedure for Displaying and Setting Custom Macro Common Variables
1 Press function key
OFFSET
SETTING
.
2 Press the continuous menu key
, then press chapter selection
soft key
[MACRO].The following screen is displayed:
NO. NAME DATA COMMENT
500 TOOL 0.000
501 STANDARD X 0.000 *BOLT HOLE
502 STANDARD Y 0.000 CIRCLE*
503 RADIUS 0.000 SET PATTERN
504 S. ANGL 0.000 DATA TO VAR.
505 HOLES NO 0.000 NO.500–505.
506 0.000
507 0.000
ACTUAL POSITION (RELATIVE)
X 0.000 Y 0.000
VAR. : BOLT HOLE O0001 N00000
> _
MDI **** *** ***
16:05:59
[ MACRO ] [ MENU ] [ ] [ ] [(OPRT
)]
3 Move the cursor to the variable number to set using either of the
following methods:
– Enter the variable number and press soft key
[NO.SRH].
– Move the cursor to the variable number to set by pressing page keys
PAGE
and/or
PAGE
and cursor keys , , , and/or .
4 Enter data with numeric keys and press soft key
[INPUT].
5 To set a absolute work coordinate in a variable, press address key
X
,
Y
, or
Z
, then press soft key [INP.C.].
6 To set a blank in a variable, just press soft key
[INPUT]. The value
field for the variable becomes blank.
11.4.5
Procedure for CRT/MDI
MACRO
Continuous menu key