APPENDIX
G. ALARM LIST
B–62094E/04
436
Number ContentsMessage
090 REFERENCE RETURN
INCOMPLETE
The reference position return cannot be performed normally because
the reference position return start point is too close to the reference
position or the speed is too slow. Separate the start point far enough
from the reference position, or specify a sufficiently fast speed for
reference position return.
092 AXES NOT ON THE REFERENCE
POINT
The commanded axis by G27 (Reference position return check) did
not return to the reference position.
100 PARAMETER WRITE ENABLE On the PARAMETER(SETTING) screen, PWE(parameter writing en-
abled) is set to 1. Set it to 0, then reset the system.
101 PLEASE CLEAR MEMORY The power turned off while rewriting the memory by program edit op-
eration. If this alarm has occurred, press <RESET> while pressing
<PROG>, and only the program being edited will be deleted.
Register the deleted program.
110 DATA OVERFLOW The absolute value of fixed decimal point display data exceeds the
allowable range. Modify the program.
111 CALCULATED DATA OVERFLOW The result of calculation result is out of the allowable range.
(–10
47
to –10
–29
, 0, and 10
–29
to 10
47
).
112 DIVIDED BY ZERO Division by zero was specified. (including tan 90°)
113 IMPROPER COMMAND A function which cannot be used in custom macro is commanded.
Modify the program.
114 FORMAT ERROR IN MACRO There is an error in other formats than <Formula>.
Modify the program.
115 ILLEGAL VARIABLE NUMBER A value not defined as a variable number is designated in the custom
macro.
This alarm is given in the following cases:
1. The header corresponding to the specified machining cycle
number called is not found.
2. The cycle connection data value is out of the allowable
range (0 – 999).
3. The number of data in the header is out of the allowable
range (0 – 32767).
4. The start data variable number of executable format data
is out of the allowable range (#20000 – #85535).
5. The storing data variable number of executable format
data is out of the allowable range (#85535).
6. The storing start data variable number of executable format
datais overlapped with the variable number used in the
header.
Modify the program.
116 WRITE PROTECTED VARIABLE The left side of substitution statement is a variable whose substitution
is inhibited. Modify the program.
118 PARENTHESIS NESTING ERROR The nesting of bracket exceeds the upper limit (quintuple).
Modify the program.
119 ILLEGAL ARGUMENT The SQRT argument is negative, BCD argument is negative, or other
values than 0 to 9 are present on each line of BIN argument.
Modify the program.
122 DUPLICATE MACRO MODAL–CALL The macro modal call is specified in double.
Modify the program.
123 CAN NOT USE MACRO COMMAND
IN DNC
Macro control command is used during DNC operation.
Modify the program.
124 MISSING END STATEMENT DO – END does not correspond to 1 : 1. Modify the program.
125 FORMAT ERROR IN MACRO <Formula> format is erroneous. Modify the program.
126 ILLEGAL LOOP NUMBER In DOn, 1x nx3 is not established. Modify the program.