B–63130EN/01
1. PARAMETERS OF THE PRESS FUNCTION
7
Each of these parameters set the time interval by which setting of the PF
signal to start pressing to 1 precedes completion of Y–axis positioning for
the corresponding distance level. (Function to advance setting of PF
signal)
The parameters are validated when parameter KLV (No. 16050, #7) is set
to 1.
For the positioning distance, set the descriptions of data 16055 to 16066.
Address
16027
Time interval by which setting of PF to 1 precedes completion of C–axis
positioning for the distance of level 1.
16028
Time interval by which setting of PF to 2 precedes completion of C–axis
positioning for the distance of level 2.
16029
Time interval by which setting of PF to 3 precedes completion of C–axis
positioning for the distance of level 3.
Data type: Byte
Unit of data: msec
Valid data range: 0 to 120
Each of these parameters set the time intarval by which setting of the PF
signal to start pressing to 1 precedes completion of C–axis positioning for
the corresponding distance level. (Function to advance setting of PF
signal)
The parameters are validated when parameter KLC (No. 16050, #4) is set
to 1.
For the positioning distance, see the description of data 16140 and 16141.
Positioning
Time set in the parameter
PF
(Function to advance setting of PF signal)
If the time set here is longer than the time required for deceleration, the
PF signal is set to1 when decelaration starts.
In simultaneous positioning for the X, Y, and C axes, the PF signal is set
to 1 when the individual conditions for the X, Y, and C axes are all
satisfied.