1. PARAMETERS OF THE PRESS FUNCTION
B–63130EN/01
4
#7 #6 #5 #4 #3 #2 #1 #0Address
16003 NED DPE TCF
Data type: Bit
TCF After the OP signal indicating that automatic operation is in
progress is set from 0 to 1, the PF signal to start pressing is set
to 1:
0: Only when a T command is found.
This status is the same as the status in which the PFW
signal to wait for the start of pressingis set to 1.
1: Even if no T commands are found.
DPE The relationship between the *PE signal to stop pressing and the
EPE signal for ignoring the signal to stop pressing is as follows:
0: *PE is always validated irrespective of the status of EPE.
1: *PE is validated when EPE is set to 1, and invalidated
when EPE is set to 0.
NED After the last positioning ends in a nibbling block, the PF signal
to start pressing is set to 0:
0: When the contact of the *PE signal to stop pressing is set
to 0.
1: When the two contacts of the *NFIN signal to complete
punching for continuous pressing and the *PE signal stop
pressing are set to 0.
Address
16008 M code for setting the forming mode
16009 M code for canceling the forming mode
Data type: Byte
Valid data range: 1 to 97
Parameter 16008 sets the M code for setting the forming mode.
Parameter 16009 sets the M code for canceling the forming mode.
Address
16010 Upper limit of the position deviation at which PF is set to 1
Data type: Word axis
Unit of data: Units of detection
Valid data range: 0 to 32767
For each axis, parameter 16010 sets the upper limit of the positional
deviation at which the PF signal to start pressing is set to 1. When the
absolute value of the positional deviation does not exceed this highest
limit, PF is set to 1.
Parameter 16010 is validated when parameter PFE (No. 16001, #1) is set
to 1.
NOTE
The parameter can only be set for the X, Y, and C axes.