• Modification of variables
Variable to which no reference address is defined was made in
conversion when the address cannot be used in target PMC model.
Please define appropriate reference address to it.
To define reference address to the variable, select the variable and
edit it in Variable list displayed in Variable tab in Navigator.
However, if there are many variables to define reference address,
following operation is recommended.
1) Select all variables in Variable tab in Navigator and copy
them.
2) Paste the copied data to spreadsheet or text editor and edit
them.
3) Copy all the data on spreadsheet or text editor, and paste
back to Variable tab in Navigator.
If the symbol cannot be converted normally to variable name, the
variable is named base on its reference address. At this time,
Comment data contains the original symbol strings defined in
FANUC LADDER-III is inserted at the net where the address is
used. %CS is automatically inserted at the beginning of such
comment to recognize. Please change its variable name if you
need.
• Input of I/O assignment data
Please input I/O assignment data newly on FANUC
LADDER-IIIC because I/O assignment data is not converted by
the tool.
• Confirmation of workings
Please confirm if the converted LD program works correctly on
the target.