EDIT
SHEET
DRAW. NO.
CUST
TITLE
16i/18i/21i analog servo interface
unit connection material
A-77372EN
1.6 Power connections
1.6.1 Power Connection
The power of analog servo interface unit must be supplied from external power supply 24VDC.
24VDC are supplied through the connector CP11L. The power can be supplied from
CP11M to the next unit.
1.6.2 Power supply rating
Power Supply of 24 VDC±10%(including instantaneous voltage and ripple voltage )
one basic unit one basic unit+one expansion unit
Type F 0.7A 1.0A
Type M 1.2A(Note) 2.0A(Note)
Note) In case of type M, 24VDC 0.25A per one axes is included for analog servo amplifier.
1.6.3 Heat generated
one basic unit one basic unit+one expansion unit
Type F 10W 14W
Type M 17W 28W
CP11L
AMP Japan
1-178288-3 (Housing)
Analog servo interface unit
External power supply
CP11L
1 +24V
2 0V
3
DC24V+10%,-10%
(including an
instantaneous value
Cable
Recommended cable : A02B-0124-K830 (5m)
With M3 terminal for External power supply
03 00.8.10 Jinnai 1.6.2 and 3 added.
16
GND1
GND1 is signal ground of analog servo
interface unit. Connect to the earth plate with
Fasten terminal (A02B-0166-K330).
External power supply