TITLE
16i/18i/21i analog servo interface
unit connection material
A-77372EN
5. Setting Address Conversion Table for slave number
The value of Address conversion Table for Slave 1
The value of Address conversion Table for Slave 2
The value of Address conversion Table for Slave 3
The value of Address conversion Table for Slave 4
The value of Address conversion Table for Slave 5
The value of Address conversion Table for Slave 6
The value of Address conversion Table for Slave 7
The value of Address conversion Table for Slave 8
The value of Address conversion Table for Slave 9
The value of Address conversion Table for Slave 10
Data type : Byte
Data range : 0-7, 16, 40, 48
Set the value of Address Conversion Table(ATR) for slave number 1 to10.
The amplifier or interface unit connected to 16i/18i/21i by the optical cable is called
“Slave”. The slaves are numbered 1 to 10 from near side of 16i/18i/21i to the far side.
Each one axis servo amplifier or one interface unit (with or without the extension
unit) consists of one slave. Two axes amplifier consists of two slaves and three axes
amplifier consists of three slaves.
The analog servo amplifier is numbered as if it was connected from the terminal
slave (the most far slave from CNC). Each one-axis analog servo amplifier is
numbered one slave number. For example, if the terminal unit connected to FSSB is
slave 5, the analog servo amplifiers are numbered from 6. (Refer to the example
described later.)
This parameter is set as follows.
<> In case of amplifier (including analog amplifier):
Set (the value of No.1023-1).
<> In case of interface unit :
Set 16 for the first Pulse Module (near from 16i/18i/21i) and 48 for the second Pulse
Module (far from 16i/18i/21i).
<> In case of no slave :
Set 40.