EDIT
SHEET
DRAW. NO.
CUST
TITLE
16i/18i/21i analog servo interface
unit connection material
A-77372EN
4. Setting of bit parameter
Data type : Bit
FSL The interface type between servo amplifier and servo software is
0 : Fast type
1 : Slow type
PM1 At this axis, the first interface unit is
0 : Not used
1 : Used
PM2 At this axis, the second interface unit is
0 : Not used
1 : Used
The total interface unit number which can be connected to 16i/18i/21 is less than or
equal to two. A near unit is the first and a far one is the second. (In the case of using
an extension unit, a basic unit and an extension unit are considered as one unit.) At
the axis using an interface unit, set 1 to PM1 or PM2 alternatively according to which
interface unit is connected. (Accordingly, either PM1 or PM2 of the axis connected to
analog servo is 1.)
Notice
In case of analog servo axis, set 0 to this parameter.
(Set an appropriate value to the axis connected to digital servo
according to parameter manual.)
Notice
In case of using an interface unit, it is necessary to set the connector
number (parameter No.1936, 1937) separately.
21