4. DESCRIPTION OF PARAMETERS
B–63670EN/01
12
#7
TEM15009
#6
BCG
#5
BEM
#4
AFZ
#3
BS2
#2
BS1
#1
AS2
#0
AS1
[Data type] Bit
These parameters are related to the laser gas mixture function, which store
and monitor the operating states of the mixer. The parameters are
automatically set and need not be set manually.
AS2, AS1 Indicate the state of tank A.
AS2 AS1
0 0 : Tank A is being supplied with gases.
0 1 : Tank A is mixing the gases.
1 0 : Tank A is supplying the mixed gas.
1 1 : Tank A is being prepared for gas supply.
BS2, BS1 Indicate the state of tank B.
BS2 BS1
0 0 : Tank B is being supplied with gases.
0 1 : Tank B is mixing the gases.
1 0 : Tank B is supplying the mixed gas.
1 1 : Tank B is being prepared for gas supply.
AFZ In calculation for actual cutting feedrate display, the Z–axis is:
0 : Included.
1 : Not included.
BEM The supply pressure of the gas cylinder:
0 : Has fallen.
1 : Is normal.
BCG The gas cylinder:
0 : Has been replaced.
1 : Has not yet been replaced.
TEM The supply pressure of the tank:
0 : Has fallen.
1 : Is normal.
#7
OVE15010
#6 #5
TRG
#4 #3 #2 #1 #0
[Data type] Bit
TRG The trigger pulse command control function is:
0 : Disabled.
1 : Enabled.
OVE Edge machining and feedrate clamp by arc radius:
0 : Cannot be used at the same time.
1 : Can be used at the same time.