B–63670EN/01
4. DESCRIPTION OF PARAMETERS
75
15730 Distance of a single ramp–up step
[Data type] Word
[Unit of data]
Increment system Unit IS–A IS–B IS–C
Metric input mm 0.01 0.001 0.0001
Inch input inch 0.001 0.0001 0.00001
[Valid data range] 0 to 65000
Specify the distance of a single ramp–up step during step control.
15731 Laser power of ramp–up step 1
15732 Laser power of ramp–up step 2
15733 Laser power of ramp–up step 3
15734 Laser power of ramp–up step 4
15735 Laser power of ramp–up step 5
15736 Laser power of ramp–up step 6
15737 Laser power of ramp–up step 7
15738 Laser power of ramp–up step 8
15739 Laser power of ramp–up step 9
15740 Laser power of ramp–up step 10
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
Specify the laser powers of the ramp–up steps during step control.
15745 Distance of a single ramp–down step
[Data type] Word
[Unit of data]
Increment system Unit IS–A IS–B IS–C
Metric input mm 0.01 0.001 0.0001
Inch input inch 0.001 0.0001 0.00001
[Valid data range] 0 to 65000
Specify the distance of a single ramp–down step during step control.
4.32
THE STEP CONTROL
FUNCTION