B–63670EN/01
4. DESCRIPTION OF PARAMETERS
65
15638 Start address of teaching box DI area
15639 Start address of teaching box DO area
[Data type] Word
[Unit of data]
[Valid data range] 1 to 999
The DI/DO area can be assigned to a desired address of the internal relay
area (R area). When an address is specified in parameter No. 15638 or
15639, the area is assigned, starting from the address. This parameter is
effective when bit 1 (TBX) of parameter No. 15641 is 1.
15640 Channel of teaching box
[Data type] Byte
[Unit of data]
[Valid data range] 1, 2
Specify the channel to which the teaching box is connected.
#7
15641
#6 #5 #4 #3
TBO
#2
TBA
#1
TBX
#0
TBE
[Data type] Bit
TBE As the channel of the teaching box, the right to occupy the RS–232C port is:
0 : Always held by the CNC. (Current setting)
1 : Switchable by the TBES signal (G226, #6).
TBX The areas used to access DI/DO signals from the teaching box:
0 : Are fixed.
1 : Can be expanded.
TBA The transfer status to the extended battery–powered memory is:
0 : Not output. (Parameter No. 15642 is invalid.)
1 : Output. (Parameter No. 15642 is valid.)
TBO In the teaching box, an eight–digit program number is:
0 : Not used.
1 : Used. (The eight–digit program number option is necessary.)
4.28