B–63670EN/01
4. DESCRIPTION OF PARAMETERS
25
15136 Assist gas pressure
[Data type] Word
[Unit of data] 0.01 MPa or 0.1 kg/cm
2
[Valid data range] 0 to 255
Specify an assist gas pressure.
15137 Stabilization time of the assist gas pressure for piercing
[Data type] Word
[Unit of data] 10 milliseconds
[Valid data range] 0 to 32767
Specify the stabilization time of the assist gas pressure for piercing.
15138 Assist gas pressure for piercing
[Data type] Word
[Unit of data] 0.01 MPa or 0.1 kg/cm
2
[Valid data range] 0 to 255
Specify an assist gas pressure for piercing.
15139 Assist gas stop time
[Data type] Word
[Unit of data] 10 msec
[Valid data range] 0 to 32767
Specify the wait time in which the assist gas is stopped.