EDIT.
SHEET
DRAW. NO.
CUST.
TITLE
5
29
DESCRIPTIONDESIG.DATE
I/O module type-2 fo
Connector board
Connection manual
A-80950E
FANUC LTD
4. Module Specifications
Name Drawing No. Specifications
I/O module type-2
(Basic module B1)
A03B-0815-C040 DI/DO=48/32
With MPG interface
I/O module type-2
(Basic module B2)
A03B-0815-C041 DI/DO=48/32
Without MPG interface
I/O module type-2
(Expansion module E1)
A03B-0815-C042 DI/DO=48/32
Fuse (accessory) A03B-0815-K002 1A (For Basic module)
Inter-module
Flat cable
A03B-0815-K102 35mm long
Suitable module interval of 40mm
5. Installation conditions
Ambient
temperature
for the unit
Operation: 0℃ to 55℃
Storage and transportation: -20℃ to 60℃
Temperature
change
1.1℃/minute maximum
Humidity Normal condition: 75%(relative humidity)
Short term(within one month): 95% (relative humidity)
Vibration Operation : 0.5G or less
FANUC conducted evaluation test under the following donditions:
10 to 58Hz: 0.075mm(amplitude)
58 to 500Hz: 1G
Direction of vibration: Each of the X,Y,Z directions
Number of sweep cycles: 10
Conforminf to IEC68-2-6
Atmosphere Normal machining factory environment(For use in an environment with
relatively high levels of dust, coolant, organic solutions and so forth,
additional measures are required.)
Other
conditions
(1) Use each I/O module in a completely sealed cabinet.
(2) For ventilation within each I/O module, module interval must be 40mm
or more. Moreover for ventilation, allow a clearance of 50mm or more
aboveand below each module. Never place a device that generates a
large amount of heat below an I/O module.
(3)Install Basic module left side of Expansion module in front view.
6. Power supply rating
Module
Power supply
voltage
Power supply
rating
Remarks
Basic module
0.3A+7.3mA×DI Number of DI
points with DI=ON
Expansion module
DC24V±10% is fed
through the I/O
connector
(CB161,CB162);
±10% includes
momentary variations
and ripples.
0.2A+7.3mA×DI Number of DI
points with DI=ON