6. SERVO CHECK BOARD
B–65195EN/01
START-UP PROCEDURE
34
Maximum
current
Signal output
for maximum
current
Ap/V
Applicable
servo moter
12Ap 4.44V 2.7 α0.5, α1/3000
α/2000, α2/3000
20Ap 4.44V 4.5 αC3/2000, αC6/2000, αC12/2000
40Ap 4.44V 9 α12HV, α22HV, α30HV
αC22/1500, αC30/1200
αM3/3000
α3/3000, α6/2000
α12/2000, α22/1500
αL3/3000
80Ap 4.44V 18 αM6/3000, αM9/3000
α6/3000, α12/3000
α22/2000, α30/1200
αL6/3000, αL9/3000
130Ap 4.44V 29 α22/3000, α30/2000, α30/3000
α40/2000
αL25/3000, αL50/2000
Root mean square value (RMS) = TCMD signal output (Ap) 0.71
(7) TSA signal
The TSA signal outputs a motor speed.
Signal Conversion 3750 rpm/5V
If the TSA signal is clamped at 5 V, check whether the following
parameter is specified.
Be sure to specify 0.
1726
Not used
2115