B–65195EN/01
2. COMPATIBILITY OF THE SVU
AND SVUC WITH THE
C SERIES AMPLIFIER
COMPATIBILITY OF THE SVU
AND SVUC WITH THE
C SERIES AMPLIFIER
64
2
COMPATIBILITY OF THE SVU AND SVUC WITH THE C
SERIES AMPLIFIER
Table 1 lists the differences of the SVU and SVUC from the C series
amplifier. When replacing the C series amplifier with the SVU or
SVUC,observe the cautions listed below.
Table 1
Item
SVUC SVU
Outline Common to
C series.
Common to C series.
Interface of ESP Common to
C series.
DC24V
(Connector : CX4)
Interface of NC Type A interface
Type B interface
Type A interface
Type B interface
Surge absorber to
protect Input
Common to
C series.
None. External surge
absorber is required.
MCC confirmation
contact
b contact except for
SVUC1-130
b contact except for
SVUC1-130
TUV Not qualified Qualified
UL/CSA Qualified Qualified
Connection and
cables
Common to
C series.
Common to C series
except for ESP.
Connector location Much the same as
C series.
Much the same as
C series.
Terminal location Common to
C series.
Common to C series.
Application to
S series motor
Allowed Not allowed
Note 1 : Interface of ESP (Emergency Stop)
Type Input Terminal Signal Name
C series amplifier 1 φ AC100V T1 (5-6) 100A-100B
SVU DC24 CX4 (2-3) ESP, +24V
SVUC 1 φ AC100V T1 (5-6) (100A) - (100B)
Note 2 : Interface of NC
C series amplifier is available to Type A interface only.
The connectors JV1B (L-axis) and JV2B (M-axis) in SVU and
SVUC correspond to the connectors CN1 (L- axis) and CN2
(M-axis) in C series amplifier.
Note 1
Note 2
Note 3