B–65195EN/01
4. REPLACING THE FUSE
TROUBLESHOOTING AND RECOVERY
59
4
REPLACING THE FUSE
When replacing the fuse,keep the power supply switched off. Also make
sure that the “CHARGING” LED (red) beside the circuit breaker on the
servo amplifier front panel is off.
When replacing the fuse,keep the power supply switched off.
Also make sure that the “CHARGING” LED (red) beside the
circuit breaker on the servo amplifier front panel is off.
Remove the plastic cover on the left hand side.
Replace the fuse near the 7-segment LED.
(See Appendix NO TAG.)
D For SVU-130, SVUC-130
Use Name Qty. Specification
For control power supply FU2 1 FANUC : A06B-6089-K250
For fan FU1 1 MAKER : HM50 250V F5.0A Daito
D For all
Use Name Qty. Specification
For control power supply FU1 1 FANUC : A06B-6089-K250
MAKER : HM50 250V F5.0A Daito
IMPORTANT
Replacement procedure