FANUC Series16i /18i – MB/TB
Retract for high-speed remote buffer
-78086EN/03
2000.03.15
02 2005.02.22 Out of frame 2 is added
03 2005.11.04 Out of frame 3 is corrected
4. Parameters
Number #7 #6 #5 #4 #3 #2 #1 #0
7503
RNRST
[ Data type ] Bit
RNRST In the state of reset after retraction
with operating the high-speed remote buffer,
the reset signal RST(F0001.1) is:
0 : Output.
1 : Not output.
Number #7 #6 #5 #4 #3 #2 #1 #0
7502 RBDEC
[ Data type ] Bit
RBDEC At the deceleration of the retract function during high-speed remote buffer,
0 : The deceleration is started when the standard axis for retract (parameter
No.7524) is passed the absolute position (parameter No.7525).
1 : The deceleration is started in accordance with the movement end of the retract
value (parameter No.7522).
Number
7521 Time constant for retract
[ Data type ] Word axis
[ Unit of data ] ms
[ Valid data range ] 0 to 4000
At the retract operation of the high-speed remote buffer, the time constant of each
axis of a linear
acceleration/deceleration of a time constant type is set. This
parameter is used at an
acceleration/deceleration of the retract value movement
and a
deceleration of the stop movement
2