4. DESCRIPTION OF PARAMETERS
B–63090EN/02
136
RAL When programs are registered through the reader/puncher interface
0 : All programs are registered.
1 : Only one program is registered.
REP Action in response to an attempt to register a program whose number is
the same as that of an existing program
0 : An alarm is generated.
1 : The existing program is deleted, then the new program is registered.
Note that if the existing program is protected from being edited, it is
not deleted, and an alarm is generated.
PUO When address O of a program number is output in ISO code:
0 : “:” is output.
1 : “O” is output.
N99 With an M99 block, when bit 6 (NPE) of parameter No.3201 = 0, program
registration is assumed to be:
0 : Completed
1 : Not completed
NPE With an M02, M30, or M99 block, program registration is assumed to be:
0 : Completed
1 : Not completed
MIP Program registration by external start signal (MINP) :
0 : Not performed.
1 : Performed.
#7
3202
#6
PSR
#5
CPD
#4
NE9
#3
OSR
#2
CND
#1
OLV
#0
NE8
[Data type] Bit
NE8 Editing of subprograms with program numbers 8000 to 8999
0 : Not inhibited
1 : Inhibited
The following edit operations are disabled:
(1) Program deletion (Even when deletion of all programs is specified,
programs with program numbers 8000 to 8999 are not deleted.)
(2) Program output (Even when outputting all programs is specified,
programs with program numbers 8000 to 8999 are not output.)
(3) Program number search
(4) Program editing of registered programs
(5) Program registration
(6) Program collation
(7) Displaying programs
OLV When a program other than the selected program is deleted or output:
0 : The display of the selected program is not held.
1 : The display of the selected program is held.
CND By using the [CONDENSE] soft key on the program directory screen, the
program condensing operation is:
0 : Not performed. (The [CONDENSE] soft key is not displayed.)
1 : Performed.