B–63090EN/02
4. DESCRIPTION OF PARAMETERS
79
Rp
Rc
Path of the
cutter’s center
Programmed path
Fig. 4.16 (a) Rp and Rc
If Rc is too small in comparison with Rp, such that Rc/Rp 8 0, the cutter
will stop. To prevent this, a minimum deceleration ratio (MDR) is set.
1711
Angle (θp) used to recognize an inner corner in inner corner override
[Data type] Byte
[Unit of data] Degree
[Valid data range] 1 to 179 (standard value = 91)
This parameter sets the angle used to recognize an inner corner for inner
corner override by automatic corner override.
1712
Amount of override for an inner corner
[Data type] Byte
[Unit of data] %
[Valid data range]
1 to 100 (standard value = 50)
Set the amount of override for an inner corner.
1713
Distance Le from the starting point in inner corner override
[Data type] Word
[Unit of data]
Increment system IS–A IS–B IS–C Unit
Millimeter input 1 0.1 0.01 mm
Inch input 0.1 0.01 0.001 inch
[Valid data range] 0 to 3999
Set distance Le from the starting point in an inner comer for corner
override.
1714
Distance Ls up to the ending point in inner corner override
[Data type] Word
[Unit of data]
Increment system IS–A IS–B IS–C Unit
Millimeter input 1 0.1 0.01 mm
Inch input 0.1 0.01 0.001 inch