B–63090EN/02
4. DESCRIPTION OF PARAMETERS
297
#7
6801
#6
EXG
EXT
#5
E1S
E1S
#4 #3
EMD
#2
LFV
#1
TSM
#0
M6E
[Data type] Bit
TSM When a tool takes several tool numbers, life is counted in tool life
management:
0 : For each of the same tool numbers.
1 : For each tool.
LFV Specifies whether life count override is enabled or disabled when the
extended tool life management function is used.
0 : Disabled
1 : Enabled
EMD An asterisk (*) indicating that a tool has been expired is displayed,
0 : When the next tool is selected
1 : When the tool life is expired
E1S When the life of a tool is measured in time–based units:
0 : The life is counted every four seconds.
1 : The life is counted every second. (The maximum life is 1075
(minutes).)
NOTE
This parameter is valid when bit 2 (LTM) of parameter
No.6800 is set to 1.
EXT Specifies whether the extended tool life management function is used.
0 : Not used
1 : Used
EXG Tool life management data registration by G10 (T series) is:
0 : Performed after the data for all tool groups has been cleared.
1 : Performed by adding/changing or deleting the data for a specified
group.
NOTE
When EXG = 1, address P in the block including G10 can be
used to specify whether data is to be added/changed or
deleted (P1: add/change, P2: delete). When P is not
specified, the data for all tool groups is cleared before the
tool life management data is registered.
M6E When a T code is specified in the same block as M06
0 : The T code is processed as a return number or as a group number
selected next. Either is set by parameter M6T No.6800#7.
1 : The tool group life is counted immediately.