3.MESSAGE TRANSMISSION SPECIFICATION B-64164EN/01
- 68 -
Virtual address space for word block data with confirmation
Table 3-1 Virtual Address Space for Word Block Data with Confirmation
Allocation in PMC
Symbol Type of signal
Address
(decimal)
Virtual address
space (hexadecimal)
Symbol
Remarks
Type of
signal
X Signal from machine to PMC X0000or higher 01000000hor higher Read only
Y Signal from PMC to machine Y0000or higher 01002000hor higher Read only
F Signal from CNC to PMC F0000or higher 01004000hor higher Read only
G Signal from PMC to CNC G0000or higher 01006000hor higher Read only
R Internal relay R0000or higher 01008000hor higher Read/write
D Data table D0000or higher 0100A000hor higher Read/write
1st
PMC
E Extra relay E0000or higher 0100C000hor higher Read/write
X Signal from machine to PMC X0000or higher 01100000hor higher Read only
Y Signal from PMC to machine Y0000or higher 01102000hor higher Read only
F Signal from CNC to PMC F0000or higher 01104000hor higher Read only
G Signal from PMC to CNC G0000or higher 01106000hor higher Read only
R Internal relay R0000or higher 01108000hor higher Read/write
D Data table D0000or higher 0110A000hor higher Read/write
2nd
PMC
E Extra relay E0000or higher 0110C000hor higher Read/write
X Signal from machine to PMC X0000or higher 01200000hor higher Read only
Y Signal from PMC to machine Y0000or higher 01202000hor higher Read only
F Signal from CNC to PMC F0000or higher 01204000hor higher Read only
G Signal from PMC to CNC G0000or higher 01206000hor higher Read only
R Internal relay R0000or higher 01208000hor higher Read/write
D Data table D0000or higher 0120A000hor higher Read/write
3rd
PMC
E Extra relay E0000or higher 0120C000hor higher Read/write
NOTE
1 The first PMC to third PMC depend on the PMC
option configuration. An attempt to access
nonexistent PMC space results in an error.
2 Only installed address space in the PMC can be
accessed. Check PMC address space before
use.