B–62073E–1/042. INTERFACE BETWEEN CNC AND PMC–NA OR NB
– 274 –
NOTE 6 The following table lists the override values which can be selected by soft switches for feedrate
override.
JF00 – JF70 (JF0 – JF7)
7114 1110
Override value
(%)
0 1111 1111 0
1 1111 0101 10
2 1110 1011 20
3 1110 0001 30
4 1101 0111 40
5 1100 1011 50
6 1100 0011 60
7 1011 1001 70
8 1010 1111 80
9 1010 0101 90
10 1001 1011 100
11 1001 0001 110
12 1000 0111 120
13 0111 1101 130
14 0111 0011 140
15 0110 1001 150
16 0101 1111 160
17 0101 0101 170
18 0100 1011 180
19 0100 0001 190
20 0011 0111 200
(0 : Signal LOW , 1 , Signal HIGH)
2.3.62 Run hour display
Besides the integrator for the time during automatic operation start and the integrator for the cutting time, an
integrator which starts with an input signal from the PMC is prepared in the control unit. The integrated value
can be displayed on the CRT and preset by MDI operation.
(a) General–purpose integrator start signal (TMRON)
[Classification]
Input signal
[Function] This signal starts the general–purpose integrator in the control unit. The integrator can be
optionally used for the machine.
[Operation] While this signal is on, the integrator operates and integrates the time.
[Use] This signal is used for displaying an integrated value, for example, the total time for which
coolant has been used.