2002/03/11 T.Inagaki E.Genma
A-78708EN
FANUC Series 16i/18i –TB
FANUC Series 16i/18i/21i –MB
Machining condition selecting function
Title
Drawing No.
Page
Descri
tionDate Edit
15/31
02 020423 T.Inagaki Make an overall revision
Max allowable acceleration
The allowable acceleration is set. It is used when the feedrate is determined by
acceleration.
[Valid data range] :0-99999.999(Unit: 1mm/sec
2
)
[Data size] :Dword axis
On HPCC/AI-HPCC/AI-nano-HPCC mode, this item is applied for acc/dec
during circular interpolation.
On APC/AICC/AI-APC/AI-nano mode, when Prm.13600#0(MCR) is set to 0,
arc radius-based feedrate clamping parameters are automatically set.
When this item is set, following parameters are changed.
[APC/AICC/AI-APC/AI-nano]
Prm.13620(LV1 : highest priority to velocity)
Prm.13621(LV10: highest priority to precision)
[HPCC/AI-HPCC/AI-nano HPCC]
Prm.13670(LV1 : highest priority to velocity)
Prm.13671(LV10: highest priority to precision)
By selecting the precision level, following parameters are set.
[APC]
(Prm.1730)
2
10
Effective value =
Prm.1731
×
36
(IS-B)
(Prm.1730)
2
100
=
Prm.1731
×
36
(IS-C)
Note) Parameters No.1730/1731 are automatically set only
when parameter No.13600#0(MCR) is set to '0'.
[AICC/AI-APC/AI-nano]
Prm.1432 100 (Prm.1730)
2
10
Effective value =
Prm.1785
×
6
=
Prm.1731
×
36
(IS-B)
(Prm.1730)
2
100
=
Prm.1731
×
36
(IS-C)
Note) Parameters No.1730/1731 are automatically set only
when parameter No.13600#0(MCR) is set to '0'.
[HPCC/AI-HPCC/AI-nano HPCC]
Prm.1432 100
Effective value =
Prm.8470
×
6