Title
FANUC Series 30i-MODEL A
Outline
External Touch Panel(called "ETP" below) of SNP-X protocol can be
connected with Series 30i.
ETP has functions that can read out/ write in from/to PMC such control
signals as input signal(X), output, signal(Y), internalrelay(R), keep relay(K),
data table(D), Extra relay(E), timer(T), counter(C), and the function is
almost the same as operating panel of machine.
The remarkable function of ETP is drawing function.
Assignment between drawing and address(signal) can be specified freely.
For example, the data in data table can be set with the switch on the screen
which is designed to assign the setting of data table.
DATA
Push the switch
on the screen.
Data in data
table is set.
CNCETP
Details
- Connection
RS-232C serial port 2(LCD-mounted type without PC function and
Stand-alone type:JD36A, 15’LCD mounted type and LCD mounted type
with PC function:JD54) on main board is used in CNC.
Cable-A must be based on RS-232C standard, and are prepared by customer.
A-79342E
Draw
No.
03 04.11.25 Addition and correction of part of ③
02 04.08.06 Ono Addition and correction of part of ②.
Ed. Date Design Description
’
2/6
Page
External touch panel interface