5.ALARMS B-70264EN/02
- 50 -
ALM No.4065
SHUTTER ACTION
Alarm output condition
This alarm is issued if, after the LRDY state is established in the
sequence, the shutter open command does not match the shutter state.
When the shutter open signal SHOP is "1", the system is considered
normal with the shutter state signals SHON=1 and SHOF=0.
When the shutter open signal SHOP is "0", the system is considered
normal if the shutter state signals SHON=0 and SHOF=1.
Otherwise, the alarm is issued. When SHOP changes, however, the
alarm monitor is masked for the time set in parameter No. 15152
(default: 3 seconds).
Related data
DGN.961 #4 SHON Shutter open state
DGN.961 #5 SHOF Shutter closed state
DGN.973 #0 SHOP Shutter open command
F200 #4 SHTONL Shutter ON signal
F200 #3 SHTOFL Shutter OFF signal
ALM No.4066
DISCHARGING
After the discharge start (HV ON) signal is turned on, the
discharge starts. At this time, this alarm is issued if at least one
discharge tube does not discharge and causes high voltage.
Alarm output condition
When the HVON signal is turned on, the discharge tubes are started up
to the maximum specified with the bias command in six seconds. Then,
after the time set with parameter No.15222 has elapsed, the voltage of
each discharge tube is compared with the setting of parameter
No.15221. This alarm is issued if the voltage of at least one discharge
tube exceeds the setting of the parameter.
Related parameters
PRM.15220 Maximum bias command value
PRM.15221 Discharge start check voltage
PRM.15222 Discharge wait time
PRM.15223 Bias command
Related data
DGN.909-914 Discharge tube voltage and current
G222 #7 HVON Discharge start signal