01
Ed.
1999.08.03
Date
S.Hanyu
Name
Newly designed
Detail of modification
Subject
Spec.
Signal processing and parameter setting
for Machine Protection Function
at Power Failure
B-65162E/03-10
FANUC LTD
Page
3/ 7
1-2 HIGH SPEED CYCLE CUTTING
High-speed cycle machine retracting function is needed.
The retraction is controlled by High-speed cycle machine retracting signal (HSRT).
Set HSRT to “1” when Power failure detection signal (*PFL) changes from “1” to “0”
Detect power failure
*PFL
HSRT
*PFL: Power failure detection signal.
Output from the connector CX16 on Power Failure Backup Module.
HSRT: High-speed cycle machining retracting signal.
If high-speed cycle machining is under way, and retracting is enabled for the current
machining cycle (Retracting selection flag RT on the bit 7 of the data type specification
variable in the high-speed cycle header is ”1”), the control unit begins High-speed cycle
machining retracting when the HSRT is set to “1”.
The retract speed and direction, and amount of retraction are specified with the
following parameters.
After retracting ends, CNC causes automatic operation to pause or enters a retract
cycle state.
Signal address Parameter number
CNC HSRT Retract speed
and direction
Retract amount
(*1)
FS16i/18i
FS16-B/18-B/16-C/18-C
G065 #3 No.7514 No.7515
(*1) This parameter specifies a retracting distribution count for high-speed cycle
machining retracting. If the machining cycle ends before the specified distribution
count expires, retracting ends immediately. If this parameter is 0, it is assumed that
the retracting distribution cycle is indefinite, so retracting continues until the current
cycle ends.
Refer to Connection Manual (Function) and Parameter Manual of each CNC in detail.