FANUC Series 16/160i-LA/LB
Automatic aging function setting screen
Specification
A-79279E
Page
3 / 7
Recog
nition
Newly designed
Suzuki
Tokito
04.01.05 01
Item #1 corrected.
Suzuki
Tokito
04.09.29 03
A
ll revised.
Suzuki
Tokito
05.03.25 04
The items displayed in page 1 are shown as follows. A setting range in the following explanation is a
setting range to input on this screen.
Name AGING (0:OFF, 1:ON)
Meaning You can set whether automatic aging function is available or not.
Parameter
No.15008#6
Setting value 0 or 1
Name REMAINING CYCLES
Meaning It is a remaining cycles that is calculated by CNC.
Parameter
No.15334
Setting range
0~255
Name YEAR DATA
Meaning Time data. (Note #1)
Parameter
No.15335
Setting range
0~2100
Name MONTH DATA
Meaning Time data. (Note #1)
Parameter
No.15336
Setting range
0~12
Name DAY DATA
Meaning Time data. (Note #1)
Parameter
No.15337
Setting range
0~31
Name HOUR DATA
Meaning Time data. (Note #1)
Parameter
No.15338
Setting range
0~23
Note #1
These time data are renewed when laser oscillator is under LSTR status. When LSTR status is
turned off, time data at the moment are held. When automatic aging function is not available (prm.
No.15008#6=0), time data is not renewed.
Name TIME LEFT
Meaning The estimated rest time of aging function including the power calibration time is
indicated in the minute unit. Because this is an estimated value, there is some
error compared with actual execution time.
Parameter
Setting range This item can be read only. You can’t set a value in this item.
Name MANUAL MODE(0:OFF, 1:ON)
Meaning This setting item value is zero when CNC is turned on. By RUN-ON after setting
this item to "1", aging function starts according to the item "SET MANUAL
TIMES" irrespective of setting value of parameter No.15008#6 or oscillator stop
time. This item becomes zero automatically when laser oscillator becomes LSTR
status after aging function is completed. If this item is set after RUN-ON, this
settin
g
is not available and manual a
g
in
g
function set b
y
this item does not work.

Contents Summary of FANUC Series 16/160i-LA/LB Automatic Aging Function Setting Screen, Specification Additional Manual

  • Page 1FANUC Series 16/160i-LA/LB Automatic aging function setting screen Specifications 04 05.03.25 Tokito Suzuki All revised. Title FANUC Series 16/160i-LA/LB of Automatic aging function setting screen 03 04.09.29 Tokito Suzuki Item #1 corrected. Drawin Specification Drawing 01 04.01.05 Tokito Suzuki New
  • Page 21. Outline A setting screen has been added, which can show all the setting values for automatic aging function. You can see and change all the setting values for aging function and power calibration in this new setting screen. 2. Specification This setting screen consists of three pages. Page 1 and
  • Page 3The items displayed in page 1 are shown as follows. A setting range in the following explanation is a setting range to input on this screen. Name AGING (0:OFF, 1:ON) Meaning You can set whether automatic aging function is available or not. Parameter No.15008#6 Setting value 0 or 1 Name REMAINING CYC
  • Page 4This setting is determined by timing of RUN-ON. Thus the action of aging function does not change if this setting is changed when aging function is executed. Parameter - Setting value 0 or 1 Name SET MANUAL TIMES Meaning You can set the aging execution times when you start the aging function by manu
  • Page 5Name CAL. TIME Meaning Calibration time for aging function. Parameter No.15329 Setting range 0~32767 Name GAS PRESS. (50Hz) Meaning Laser gas pressure for aging function (50Hz). Parameter No.15330 Setting range 0~32767 Name GAS PRESS. (60Hz) Meaning Laser gas pressure for aging function (60Hz). Para
  • Page 6Name POWER(HALF) Meaning Laser power command for power calibration in case of using half of discharge tubes. Parameter No.15200 Setting range 0~9999 Name POWER(ALL) Meaning Laser power command for power calibration in case of using all of discharge tubes. Parameter No.15201 Setting range 0~9999 Name
  • Page 72.4. A method which makes manual aging stop When aging function starts up, the setting values of gas pressure and laser output conditions are renewed automatically. If you want to stop aging function during aging function is executed and want to execute usual start up sequence, see as follows. Both