FANUC Series 16/160i-LA/LB Automatic Aging Function Setting Screen, Specification Additional Manual Page 7

Additional Manual
Edit Date Design Contents
Title
of
Drawin
Drawing
No.
FANUC Series 16/160i-LA/LB
Automatic aging function setting screen
Specification
A-79279E
Page
7 / 7
Recog
nition
Newly designed
Suzuki
Tokito
04.01.05 01
Item #1 corrected.
Suzuki
Tokito
04.09.29 03
A
ll revised.
Suzuki
Tokito
05.03.25 04
2.4. A method which makes manual aging stop
When aging function starts up, the setting values of gas pressure and laser output conditions are
renewed automatically. If you want to stop aging function during aging function is executed and
want to execute usual start up sequence, see as follows. Both manual aging and automatic aging are
the same operation.
(a) The machine that can’t operate HV-ON(High voltage on).
1. Run-off the laser oscillator and wait till PURGE status.
2. Set the value of “MANUAL MODE” on the page 1 to “0”.
3. Set the value of “AGING” on the page 1 to “1”.
4. Set the present time to each “TIME DATA” on the page 1
5. After setting values are changed, run-on the laser oscillator again. The parameters of gas
pressure (No.15242, No.15243) are changed to the value of No.15324 and No.15325
automatically, and the parameters of power calibration condition (No.15201, No.15332,
No.15333, No.15205) are changed to the values of parameters from No.15320 to No.15323.
(b) The machine that can operate HV-ON.
1. Turn off the HV-ON
2. Set the value of “TIME LEFT” on the page 1 to “0”
3. After setting value is changed, turn on the HVON again. The parameters of gas pressure
(No.15242, No.15243) are changed to the value of No.15324 and No.15325 automatically,
and the parameters of power calibration condition (No.15201, No.15332, No.15333,
No.15205) are changed to the values of parameters from No.15320 to No.15323.
2.5. Screen changing
Page 2 and 3 can be hidden by parameter setting. When parameter No.15014#4=0, only page 1 can
be displayed and item "Manual mode" can be changed. Page 2 and page 3 cannot be displayed.
When parameter No.15014#4=1, all the pages can be displayed. Please set this parameter to 0
usually.
3. Parameter
#7 #6 #5 #4 #3 #2 #1 #0
15014 MAG
Data typebit
MAG In automatic aging function setting screen,
0:Only Page 1 can be displayed and only item "Manual mode" can be set.
The only value "2" can be set in the item "Manual times".
1:All the items of all the pages can be displayed. The value from 2 to 255 can
be set in the item "Manual times".
4. Remark
The automatic aging function setting screen can be displayed whether automatic aging function is
available.
The screen is available on and after the following software edition.
1. B8F3-09
2. B8H1-06
3. B8H5-02

Contents Summary of FANUC Series 16/160i-LA/LB Automatic Aging Function Setting Screen, Specification Additional Manual

  • Page 1FANUC Series 16/160i-LA/LB Automatic aging function setting screen Specifications 04 05.03.25 Tokito Suzuki All revised. Title FANUC Series 16/160i-LA/LB of Automatic aging function setting screen 03 04.09.29 Tokito Suzuki Item #1 corrected. Drawin Specification Drawing 01 04.01.05 Tokito Suzuki New
  • Page 21. Outline A setting screen has been added, which can show all the setting values for automatic aging function. You can see and change all the setting values for aging function and power calibration in this new setting screen. 2. Specification This setting screen consists of three pages. Page 1 and
  • Page 3The items displayed in page 1 are shown as follows. A setting range in the following explanation is a setting range to input on this screen. Name AGING (0:OFF, 1:ON) Meaning You can set whether automatic aging function is available or not. Parameter No.15008#6 Setting value 0 or 1 Name REMAINING CYC
  • Page 4This setting is determined by timing of RUN-ON. Thus the action of aging function does not change if this setting is changed when aging function is executed. Parameter - Setting value 0 or 1 Name SET MANUAL TIMES Meaning You can set the aging execution times when you start the aging function by manu
  • Page 5Name CAL. TIME Meaning Calibration time for aging function. Parameter No.15329 Setting range 0~32767 Name GAS PRESS. (50Hz) Meaning Laser gas pressure for aging function (50Hz). Parameter No.15330 Setting range 0~32767 Name GAS PRESS. (60Hz) Meaning Laser gas pressure for aging function (60Hz). Para
  • Page 6Name POWER(HALF) Meaning Laser power command for power calibration in case of using half of discharge tubes. Parameter No.15200 Setting range 0~9999 Name POWER(ALL) Meaning Laser power command for power calibration in case of using all of discharge tubes. Parameter No.15201 Setting range 0~9999 Name
  • Page 72.4. A method which makes manual aging stop When aging function starts up, the setting values of gas pressure and laser output conditions are renewed automatically. If you want to stop aging function during aging function is executed and want to execute usual start up sequence, see as follows. Both