FANUC Series 16i/18i -MA
SPECIFICATIONS FOR
ELECTRONIC GEAR BOX
AUTOMATIC PHASE SYNCHRONIZATION
EDT. DATE DESIG.
DESCRIPTION
PAGE
4 / 14
A – 77934E
NO.
TITLE
01
1999.OCT.29
NEWLY
1. Specify G81R1 to start synchronization.
When G81R1 is specified, acceleration according to the acceleration rate
set in the parameter (No.2135,2136 or No.4384,4385) is performed on the
workpiece axis (slave axis). Once the synchronization feedrate is
reached, synchronization mode signal SYNMOD is set to 1, and the
G81R1 block is terminated.
2. For cancellation, specify G80R1 while the tool is moved away from the workpiece.
3. When G80R1 is specified, the EGB mode check signal is set to 0, and
deceleration according to the acceleration rate set in the parameter (No.
2135,2136 or No.4384,4385) is started immediately. When the speed is
reduced to 0, the G80R1 block is terminated.
Note1) Linear acceleration/deceleration applies to synchronization start/cancellation.
Note2) In automatic synchronization cancellation due to Reset or P/S alarm
(No.000), deceleration is executed and synchronization is canceled.