FANUC Series 16i/18i -MA
SPECIFICATIONS FOR
ELECTRONIC GEAR BOX
AUTOMATIC PHASE SYNCHRONIZATION
EDT. DATE DESIG.
DESCRIPTION
PAGE
7 / 14
A – 77934E
NO.
TITLE
01
1999.OCT.29
NEWLY
Note3) In automatic phase synchronization, when a synchronization command is
issued again in a synchronization state, movement about the workpiece
axis is performed such that the position corresponding to the one-rotation
signal of the spindle matches the position about the workpiece axis
specified in the G81R2 synchronization start command executed first.
Note4) In automatic phase synchronization, movement is performed about the
workpiece axis from the current position to the nearest phase position in the
phase synchronization movement direction specified by the parameter.
Note5) Linear acceleration/deceleration applies to synchronization start/cancellation.
Note6) The acceleration/deceleration plus automatic phase synchronization type
can be executed by the PHS parameter, bit 6 of No.7702, without
specifying an R2 command in a G81 or G80 block.
Note7) In automatic synchronization cancellation due to Reset or P/S alarm
(No.000), deceleration is executed and synchronization is canceled.
Note8) This item is for spindle EGB.
If the control mode of the master axis is the speed control, it is necessary
to execute the position coder orientation before that the automatic phase
synchronization is started. In this case, RFCHK3 (PRM4016#7) of the
master axis must be set “0” to keep memorizing the one-rotation signal
position of the spindle in the speed control mode.
Note9) This item is for spindle EGB.
If the control mode of the master axis is Cs contouring, it is necessary to
execute the reference point return before that the automatic phase
synchronization is started.
Note10) The acceleration rate parameter(No.2135,2136 or No.4384,4385) must not
be changed in the synchronization mode.
Note11) Do not cancel the synchronous mode by the reset when this function is
used. (Set "1" in patameter No.7700#0 HBR.)