TITLE
er
es
-
,
-
AI contour control function
Specifications
EDIT. DATE DESIG. DESCRIPTION
FANUC LTD
SHEET
21/ 32
DRAW. NO.
A-63512EN
CUST.
Feedrate
Time
Parameter 1
(No.1770)
Parameter 2 (No.1771)
3. Parameter
3.1 Acceleration / deceleration before interpolation
1770 Parameter 1 for setting an acceleration for linear acceleration / deceleration
before interpolation (maximum machining speed during linear acceleration /
deceleration before interpolation)
Data type : 2-word
Unit of data :
Valid range :
In this parameter, set the maximum machining speed during linear acceleration /
deceleration before interpolation.
1771 Parameter 2 for setting an acceleration for linear acceleration / deceleration
before interpolation (time used to reach the maximum machining speed during
linear acceleration / deceleration before interpolation)
Data type : Word
Unit of data : 1 msec
Valid range : 0 to 4000
In this parameter, set the time (time constant) used to reach the speed set in parameter
No.1770.
(Note1) When 0 is set in parameter No.1770 or parameter No.1771, the linear acceleration /
deceleration before interpolation is disabled.
(Note2) In parameter No.1770 and 1771, set values that satisfy the following.
Parameter No.1770
Parameter No.1771
≥
5
Increment system Unit of data Valid range
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 ~ 240000 6 ~ 100000
Inch machine 0.1 inch/min 6 ~ 9600 6 ~ 4800