PROGRAMMING11. AUXILIARY FUNCTION
B–63514EN/01
122
Indexing of the table is performed by address B and a following 8–digit
number. The relationship between B codes and the corresponding
indexing differs between machine tool builders.
Refer to the manual issued by the machine tool builder for details.
0 to 99999999
1. To enable the use of a decimal point, set bit 0 (AUP) of parameter
No.3450 to 1.
Command Output value
B10. 10000
B10 10
2. Use bit 0 (DPI) of parameter No. 3401 to specify whether the
magnification for B output will be 1000 or 1 when a decimal
point is omitted.
Command Output value
DPI=1 B1 1000
DPI=0 B1 1
3. Use bit 0 (AUX) of parameter No. 3405 to specify whether the
magnification for B output will be 1000 or 10000 when a
decimal point is omitted for the inch Input system
(only when DPI=1).
Command Output value
AUX=1 B1 10000
AUX=0 B1 1000
When this functions is used, the B address specifying an axis movement
disabled.
11.3
THE SECOND
AUXILIARY
FUNCTIONS
(B CODES)
Explanations
D Valid data range
D Specification
Restrictions