2.NOTES ON INSTALLATION MOTOR TYPES AND USAGE B-65312EN/01
- 18 -
8 Since βi series motors are more compact than αi series motors
even though both have the same power output, the allowable
radial load of the βi series is smaller. Therefore, it is necessary
to prevent the allowable radial load of the motor from being
exceeded by using a belt that has stable transmission
characteristic even at a high speed and designing the pulley with
a large diameter. For the allowable radial load for each model,
see Chapter II.5.
Recommended belt:
Banfle scrum belt or Banflex belt manufactured by Bando
Chemical Industries Ltd (belt speeds of up to 60 m/s).
Example of belt design
Design must be made so that the static axial load by a belt that was
subject to initial wear does not exceed the allowable radial load for
each model. (A new belt is subject to initial wear after several hours
operation and the static axial load becomes equal to that for the
restretched belt in the following table.)
Motor model
β3/10000i β6/10000i β8/8000i β12/7000i
Designed power
(15 min. rated output × 1.1)
[kW] 6.1 8.3 12.1 16.5
Belt type 5M (5MS) 5M (5MS) 5M (5MS) 7M (7MS)
Pulley dia. on the spindle side (PCD) [mm] φ165 φ165 φ210 φ210
Pulley dia. on the motor side (PCD) [mm] φ132 φ132 φ168 φ168
Gear reduction ratio 0.80 0.80 0.80 0.80
Motor max. speed [min
-1
] 8,000 8,000 6,000 6,000
Belt surface speed
(at the max. motor speed)
[m/s] 55.3 55.3 52.8 52.8
Number of belt crests 4 6 7 4
Static axial load for new belts [N] 1,200 1,638 1,904 2,604
Static axial load for re-stretched
belts
[N] 923 1,260 1,464 2,003
Allowable radial load
(at the output axis center)
[N] 999 1,607 2,205 3,371
NOTE
1 Prevent oil or dust from entering between the belt
and the pulley. Otherwise, the belt may slip.
2 If the allowable radial load is exceeded, reduce the
load by using support bearings on the machine side
or directly connecting to the machine in order to
secure reliability for a extended period of time.