B-65312EN/01 MOTOR TYPES AND USAGE 5.DETERMINING THE ALLOWABLE DUTY CYCLE
- 23 -
5 DETERMINING THE ALLOWABLE DUTY
CYCLE
When machining requires the spindle to accelerate and decelerate
frequently, the average output per cycle must not exceed the
continuous rated output. The allowable duty cycle for a typical AC
spindle motor can be obtained as shown below.
Duty cycle and average output
Motor
speed
t
1
t
2
t
3
t
4
P
1
P
2
P
3
P
4
t
5
One cycle time Dt
P
1
Motor
output
P
1
, P
4
: Acceleration/deceleration output [kW]
= 15 min rated output at const. output power range × 1.1
Note 1) This is not a guaranteed value but a guideline.
P
2
: Output with no load [kW] (P
2
=0)
P
3
: Cutting output [kW]
Dt
tPtPtPtP
Pav output Average
4
2
43
2
32
2
21
2
1
+++
=
NOTE This is not a guaranteed value but a guideline.
NOTE
1 Cutting output P
3
at motor speed N which is lower
than base speed Nb shall be calculated by the
following equation.
P
3
=P
C
× Nb/N [kW] (P
C
: Actual cutting output)
2 In case that P
3
is calculated by the load indicator
voltage, use the following equation.
P
3
=P
1
× L
3
/10 [kW]
(L
3
: Load indicator voltage in cutting [V])