Title
Sheet
Draw. No.
nalog input
separate detector interface unit
7/18
FANUC LTD
A-56731E-0099
Description Desig. Date Edit.
01 050714 Matsukane
7. Specification
Order number : A06B-6061-C201
Power supply capacity : Voltage DC24V+/-10%, Current 0.9A
Method of installation : Screws or DIN rail.
8. Connection of Power supply
Power to Analog input separate detector interface unit should be supplied from an
external DC24V power supply.
When using Expansion unit of Separate detection interface unit, the power to the
Expansion unit is supplied by Analog input separate detection interface unit by the flat
cable.
The DC24V input to CP11A can be output at CP11B for use in branching. The connector
of CP11A and CP11B are in identical connector housing and the connection of those are
same. In this case, the power supply to CP11A should be equal to the sum of the rating
of Analog input separate detector interface unit and that of the unit supplied through
CP11.
CP11A
Cable
nalog input
separate detector interface unit
External power supply
DC24V regulated
power supply
DC24V+/-10%
CP11A
Tyco Electronics
1-178288-3(housing)
1-175218-5(contact)
+24V (1)
0V (2)
0V
1
3
+24V
2
Recommended cable specification: A02B-0124-K830 (5m)
(M3 crimp terminals are applied for the external power supply side.)
Select a connector
matching for the
external power supply.
GND1
External power supply