FANUC Series 30i-MODEL A
Improvement of stored stroke limit 1
1326 Coordinate II along each axis in the plus direction of stored stroke limit 1.
1327 Coordinate II along each axis in the minus direction of stored stroke limit 1
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data]Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table(A))
(When the increment system is IS-B, -999999.999 - +999999.999)
Set a coordinate along each axis of the machine coordinate system in the minus
direction of stored stroke limit 1.
When the stored stroke limit switch signal EXLM is set to 1, or the stored stroke
limit switch signal based on the axis direction signal -EXLx is set to 1, a stroke
limit check is made using this parameter instead of parameter No. 5221.
NOTE
1. Specif
diameter values for an
axes for which diamete
programming is specified.
2. The area outside the area set b
parameter No. 1326 and No.
1327 is a prohibited area.
3. The EXLM si
nal is valid onl
when bit 2
LMS
of parameter No.
1300 is set to 1.
4.
The +EXLx si
nal is valid onl
when bit 0
DLM
of paramete
No. 1301 is set to 1.
Alarm and message
Numbe
r
Message Description
OT050
0
+ OVERTRAVEL
( SOFT 1 )
Exceeded the positive side
stored stroke check 1.
OT050
1
- OVERTRAVEL
( SOFT 1 )
Exceeded the negative
side stored stroke check 1