A-79360E
Title
Draw
No.
Ed. Date Design Description
Date Jan.06.’04 Design. Apprv.
7/9
page
FANUC Series 30i-MODEL A
Improvement of stored stroke limit 1
1320 Positive (+) direction coordinate of stored stroke limit 1 of each axis I
1321 Negative (-) direction coordinate of stored stroke limit 1 of each axis I
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data]Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table(A))
(When the increment system is IS-B, -999999.999 - +999999.999)
Set the coordinate in the positive-direction machine coordinate system of stored
stroke limit 1 for each axis.
NOTE
1. Specify diameter values for any axes for which diameter
programming is specified.
2.
The area outside the area set by parameter No. 320 and
No. 1321 is a prohibited area.