FANUC Series 30i-MODEL A
Improvement of stored stroke limit 1
# 2 LMS The EXLM signal for switching stored stroke check
0: Disabled
1: Enabled
When bit 0 (DLM) of parameter No. 1301 is set to 1, the stored stroke
check 1 switch signal EXLM (G007#6) is made invalid.
# 7 BFA When the stored stroke check 1, 2, or 3 alarm is issued, an
function (T series), or a chuck/tail stock barrier (T series) alarm is
issued:
0: The tool stops after entering the prohibited area.
1: The tool stops before the prohibited area.
#7 #6 #5 #4 #3 #2 #1 #0
1301 PLC OTS NPC DLM
[Input type] Setting input
[Data type] Bit path
# 0 DLM Specifies whether to enable the axis-direction-specific stored stroke limit
switching signals +EXLx and -EXLx.
0: Disabled.
1: Enabled.
When this parameter is set to "1," the stored stroke limit switching signal EXLM,
common to all axes, is disabled.
# 6 OTS When the over travel alarm is generated,
0: “Stroke limit reached signals” is not outputted to PMC.
1: “Stroke limit reached signals” is outputted to PMC.