B–63503EN/02
9. CONNECTION TO FANUC I/O Link
118
:SIN
1
3
SIN
2
SOUT
4
6
:SOUT
5
8
7
9
(+5V)
10
0V
11
13
0V
12
0V
14
16
0V
15
18
17
(+5V)
(+5V)
19
20
JD1A
(PCR–E20MDK–SL–A)
JD1B
(PCR–E20MDK–SL–A)
JD1B
JD1A
Next slave
unit
:SIN
1
3
SIN
2
SOUT
4
6
:SOUT
5
8
7
9
(+5V)
10
0V
11
13
0V
12
0V
14
16
0V
15
18
17
(+5V)
(+5V)
19
20
Control unit preceding slave unit Main panel B
Recommended connector for cable of JD1A and JD1B on Main panel B
When the depth of the operator’s panel is 60mm min.
Recommended connector for cable:
Hirose electric FI40B–2015S (Connector)
FI–20–CV (Case)
When the depth of the operator’s panel is 80mm min.
Recommended connector for cable:
Honda: PCR–E20FA (Connector)
PCR–V20LA (Case)
Hirose electric: FI30–20S (Connector)
FI–20–CV2 (Case)
Fujitsu: FCN–247J020–G/E (Connector)
FCN–240C020–Y/S (Case)
Molex: 52622–2011 (Connector)
52624–2015 (Case)
+5V terminals are for an optical I/O Link adapter. They are not necessary
when connecting with a metal cable.
If not using the optical I/O link adapter, do not connect the +5 V pin.
Shield
SOUT
:SOUT
SIN
:SIN
0V
0V
0V
0V
SIN
:SIN
SOUT
:SOUT
0V
0V
0V
0V
1
2
3
4
11
12
13
14
3
4
1
2
11
12
13
14
Ground Plate
JD1A
Recommended wire material:
A66L–0001–0284#10P (AWG28 10 pairs)
JD1B
9.4.3.3
I/O link connection