Edit
Apprv.Desig.
Date
Design
Date
FANUC Series 30
i
/
31
i
/
32
i
-MODEL A
Temporary detaching of tool
attachment/detachiment
-90396E
2006.1.6
9/13
Sheet
Title
Draw
No.
Descri
tion
1.2 Signal
Tool attachment signal TLATA <F359#0>
[Classification] Output signal
[Function] Reports to attach a tool in automatic mode.
[Output condition] The signal turns to “1” in the following cases :
- Parameter ATA ( No. 13204#1 ) = 1 and the operation of attachment is performed on tool
attachment screen. However, the specified pot should be empty.
The signal turns to “0” in the following cases :
- Either tool attachment finish signal TLFATA or tool attachment error signal TLEATA is set
to “1”.
Tool detachment signal TLDTA <F359#1>
[Classification] Output signal
[Function] Reports to attach a tool in automatic mode.
[Output condition] The signal turns to “1” in the following cases :
- Parameter DTA ( No. 13204#2 ) = 1 and the operation of detachment is performed on tool
detachment screen. However, the specified pot should store a tool.
The signal turns to “0” in the following cases :
- Either tool detachment finish signal TLFDTA or tool detachment error signal TLEDTA is
set to “1”.
Tool attachment finish signal TLFATA <G382#0>
[Classification] Input signal
[Function] Report to finish tool attachment on automatic mode.
[Operation] When the signal is set to “1”, the control unit operates as follows :
- Tool attachment signal TLATA and magazine number signal TLMZN00~15 and Pot
number signal TLPOT00~15 turn to “0”.
Tool detachment finish signal TLFDTA <G382#1>
[Classification] Input signal
[Function] Reports to finish detaching a tool on automatic mode.
[Operation] When the signal is set to “1”, the control unit operates as follows :
- Tool detachment signal TLDTA and magazine number signal TLMZN00~15 and Pot
number signal TLPOT00~15 turn to “0”.
Tool attachment error signal TLEATA <G382#2>
[Classification] Input signal
[Function] Reports an error of the machine side when a tool is attached on automatic mode.
[Operation] When the signal is set to “1”, the control unit operates as follows :
- Tool attachment signal TLATA and magazine number signal TLMZN00~15 and Pot
number signal TLPOT00~15 turns to “0”.